Guardian_Overspeed; Guardian_Uxpowerlimit - Mercury V6 175 Diagnostic Manual

Table of Contents

Advertisement

Fault Codes

Guardian_Overspeed

Fault Type:
Horn:
Nonsticky
None
Explanation
Engine Guardian is active due to excessive engine speed.
Possible Causes
Engine is improperly propped
Engine is mounted too high
Engine is being trimmed too high
Propeller is cavitating
Summary of Fault Correction Possibilities
Install the correct propeller on the engine.
Correct the installation issues.
Refrain from trimming engine too high.
Test with alternate propeller.

Guardian_uXPowerLimit

Fault Type:
Horn:
Nonsticky
None
Explanation
Engine Guardian is active due to a helm fault. Power will be limited as the control system may be compromised.
Possible Causes
The command module has detected an issue and has enacted Guardian
Summary of Fault Correction Possibilities
Use the CDS G3 diagnostic tool to read the command module faults.
Refer to the DTS Diagnostic Manual P/N 8M0057654 for fault explanations.
Guardian_Voltage
Fault Type:
Horn:
Nonsticky
Caution
Explanation
Engine Guardian is active due to high or low battery voltage. Power will be limited to prevent engine damage.
Possible Causes
Failed alternator
Failed fusible link
Summary of Fault Correction Possibilities
Replace the alternator.
Replace the fusible link.
Page 4A-22
Guardian:
UFC:
100%
2091‑23
Guardian:
UFC:
Variable
2101‑23
Guardian:
UFC:
Variable
2111‑23
© 2018 Mercury Marine
Transmission to Helm:
No
Transmission to Helm:
Yes
Transmission to Helm:
Yes
Freeze Frame Priority:
4
Freeze Frame Priority:
4
Freeze Frame Priority:
4
90-8M0146617 eng JULY 2018

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V6 200V6 225V8 200V8 225V8 250V8 300

Table of Contents