Fault Codes
Fault
Code
Description
Mechanical shift demand
1063
sensor A
Mechanical shift demand
1064
sensor A
Mechanical demand sensor
1071
adapt A
Mechanical demand sensor
1072
adapt B
Mechanical demand sensors A
1073
and B difference
Mechanical demand sensors A
1074
and B
Mechanical shift demand
1077
sensors A and B difference
Mechanical shift demand
1078
sensors A and B
1108
Water in fuel
1109
Emergency stop
2011
Guardian
Guardian due to oil
2021
temperature
Guardian due to exhaust
2032
system temperature
2051
Guardian due to oil pressure
2081
Guardian due to overheat
2091
Guardian due to overspeed
2092
Neutral overspeed
Guardian due to power limit
2101
from helm module
2111
Guardian due to voltage
2124
Exhaust gas temperature S2
3002
Active exhaust valve
Electronic throttle control loss
3012
of control
Electronic throttle control
3013
output
Electronic throttle control
3014
sticking
Electronic shift control
3031
commanded to actual position
difference
Electronic shift control loss of
3032
control
Electronic shift control reverse
3033
adapt
Page 4A-6
Failure
Code
Description
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The input circuit for the sensor is below the valid
25
limit.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
23
A particular state or condition exists.
A temperature sensor value is higher than
20
normal.
The ECU has detected a problem when trying to
16
output a signal to this device.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
© 2018 Mercury Marine
PCM Fault Name
ShiftDmdSensor1_RangeHigh
ShiftDmdSensor1_RangeLow
ShiftDmdSensor2_RangeHigh
ShiftDmdSensor2_RangeLow
DmdSense1_NoAdapt
DmdSense2_NoAdapt
DemandSensor_Diff
Dual_DemandSen_Fault
ShiftDemandSensor_Diff
Dual_ShiftDemandSen_Fault
WaterInFuel_RangeLow
ESTOP_Active
Guardian_Active
Guardian_Oil_Temp_Derate
Guardian_EGTTemp
Guardian_OilPressure
Guardian_Overheat
Guardian_Overspeed
Neutral_Overspeed
Guardian_uXPowerLimit
Guardian_Voltage
EGT_Overtemp
AEV_OutputFault
ETC_Loss_Of_Control
ETC_OutputFault
ETC_Sticking
ESC_DesiredActualDiff
ESCLossOfControl
ESC_NoAdapt_Reverse