Summary of Fault Correction Possibilities
•
Remove the obstruction from the throttle body assembly.
•
Correct the wiring problem.
•
Replace the throttle body assembly.
ETC_TPSDisagree
Fault Type:
Horn:
Nonsticky
Critical
Explanation
The throttle position sensors do not agree.
Possible Causes
•
Wiring problem
•
Failed ETC
Summary of Fault Correction Possibilities
•
Repair the wiring problem.
•
Replace the throttle body assembly.
EncoderFaultCrankCamTrigger
Fault Type:
Horn:
Nonsticky
Critical
Explanation
Either the crankshaft position sensor (CPS) or the camshaft position sensor does not appear to be working properly.
Possible Causes
•
Wiring problem
•
Defective crankshaft position sensor
•
Defective camshaft position sensor
•
Mechanical timing problem
Summary of Fault Correction Possibilities
•
Correct the wiring problem.
•
Inspect the crankshaft position sensor.
•
Inspect the camshaft position sensor.
•
Correct the mechanical timing problem.
F ..........
FULP_OutputFault
Fault Type:
Horn:
Nonsticky
Critical
Explanation
The fuel pump does not appear to be working properly. The PCM detected a problem when trying to send a signal to the fuel
pump relay.
Possible Causes
•
Fuel pump relay wiring problem
•
Failed fuel pump relay
90-8M0146617 eng JULY 2018
Guardian:
UFC:
7%
331‑6
Guardian:
UFC:
100%
1052‑6
Guardian:
UFC:
100%
3061‑16
Transmission to Helm:
Yes
Transmission to Helm:
Yes
Transmission to Helm:
Yes
© 2018 Mercury Marine
Fault Codes
Freeze Frame Priority:
4
Freeze Frame Priority:
3
Freeze Frame Priority:
3
Page 4A-19