Fault Codes
Summary of Fault Correction Possibilities
•
Repair the open or short on CAN X (brown and yellow wires).
•
Replace the terminator resistor.
•
Replace the command module.
RxDoc11_SOH
Fault Type:
Horn:
Nonsticky
Caution
Explanation
There is a circuit problem on CAN X.
Possible Causes
•
Open or short on CAN X (brown and yellow wires)
•
Faulty terminator resistor
NOTE: Resistance across the bottom PCM engine harness pins A31 and A32 and across command module harness pins
6 and 7 should measure 58–60 ohms. Resistance across pins A31 and A32 at the PCM should show approximately 37.1K
ohms. Resistance across the command module pins 6 and 7 should show approximately 37.1K ohms.
Summary of Fault Correction Possibilities
•
Repair the open or short on CAN X (brown and yellow wires).
•
Replace the terminator resistor.
•
Replace the command module.
S ..........
Security_Device_Missing
Fault Type:
Horn:
Nonsticky
None
Explanation
The security device is missing or is providing no reading.
Possible Causes
•
Device offline
•
Wiring problem
Summary of Fault Correction Possibilities
•
Inspect the device connectors.
•
Inspect the wiring, and repair as necessary.
Security_Locked
Fault Type:
Horn:
Nonsticky
None
Explanation
The security device is locked.
Possible Causes
•
Device fob incorrect
•
Wiring problem
Page 4A-34
Guardian:
UFC:
100%
4010‑6
Guardian:
UFC:
100%
4501‑23
Guardian:
UFC:
5%
4502‑23
© 2018 Mercury Marine
Transmission to Helm:
Yes
Transmission to Helm:
No
Transmission to Helm:
No
Freeze Frame Priority:
3
Freeze Frame Priority:
3
Freeze Frame Priority:
4
90-8M0146617 eng JULY 2018