Fault Codes
Summary of Fault Correction Possibilities
Repair the open or short on CAN X (brown and yellow wires).
Replace the terminator resistor.
Replace the command module.

RxDoc11_SOH

Fault Type:
Horn:
Nonsticky
Caution
Explanation
There is a circuit problem on CAN X.
Possible Causes
Open or short on CAN X (brown and yellow wires)
Faulty terminator resistor
NOTE: Resistance across the bottom PCM engine harness pins A31 and A32 and across command module harness pins
6 and 7 should measure 58–60 ohms. Resistance across pins A31 and A32 at the PCM should show approximately 37.1K
ohms. Resistance across the command module pins 6 and 7 should show approximately 37.1K ohms.
Summary of Fault Correction Possibilities
Repair the open or short on CAN X (brown and yellow wires).
Replace the terminator resistor.
Replace the command module.
S ..........

Security_Device_Missing

Fault Type:
Horn:
Nonsticky
None
Explanation
The security device is missing or is providing no reading.
Possible Causes
Device offline
Wiring problem
Summary of Fault Correction Possibilities
Inspect the device connectors.
Inspect the wiring, and repair as necessary.

Security_Locked

Fault Type:
Horn:
Nonsticky
None
Explanation
The security device is locked.
Possible Causes
Device fob incorrect
Wiring problem
Page 4A-34
Guardian:
UFC:
100%
4010‑6
Guardian:
UFC:
100%
4501‑23
Guardian:
UFC:
5%
4502‑23
© 2018 Mercury Marine
Transmission to Helm:
Yes
Transmission to Helm:
No
Transmission to Helm:
No
Freeze Frame Priority:
3
Freeze Frame Priority:
3
Freeze Frame Priority:
4
90-8M0146617 eng JULY 2018