Fault Codes
Dual_TPS_Faults
Fault Type:
Horn:
Nonsticky
Critical
Explanation
The throttle position sensors (TPS) do not agree.
Possible Causes
•
ETC wiring problem
•
Failed throttle body assembly
Summary of Fault Correction Possibilities
•
Inspect the wiring to the ETC.
•
Replace the throttle body assembly.
E ..........
EGT_Overtemp
Fault Type:
Horn:
Nonsticky
Critical
Explanation
The value from the exhaust gas temperature (EGT) sensor is higher than normal, indicating that the exhaust manifold is
overheating.
Possible Causes
•
Restricted water flow
•
Plugged exhaust sprayer
•
Wiring problem
•
Defective sensor
Summary of Fault Correction Possibilities
•
Restore the water flow.
•
Remove debris from the sprayer.
•
Inspect the wiring.
•
Check the sensor, replace if required.
EGT_RangeHigh
Fault Type:
Horn:
Nonsticky
Caution
Explanation
The exhaust gas temperature (EGT) sensor does not appear to be working properly; the PCM received a signal that is above
the valid limit.
Possible Causes
•
Wiring problem
•
Defective sensor
Summary of Fault Correction Possibilities
•
Inspect the wiring to the sensor.
•
Check the sensor.
•
Check the exhaust sprayer outlets for obstructions.
Page 4A-14
Guardian:
UFC:
7%
311‑6
Guardian:
UFC:
10%
2124‑20
Guardian:
UFC:
100%
572‑24
© 2018 Mercury Marine
Transmission to Helm:
Yes
Transmission to Helm:
Yes
Transmission to Helm:
Yes
Freeze Frame Priority:
4
Freeze Frame Priority:
4
Freeze Frame Priority:
2
90-8M0146617 eng JULY 2018