Mercury V6 175 Diagnostic Manual page 94

Table of Contents

Advertisement

Fault Codes
Fault
Code
Description
Throttle position sensor adapt
342
B
Manifold pressure sensor using
401
time sampling
Manifold pressure sensor using
402
angle sampling
Manifold pressure sensor and
404
throttle position sensor A
rationality
Manifold pressure sensor and
405
throttle position sensor B
rationality
Manifold pressure sensor
407
barometer reading
431
Oil pressure
511
Intake air temperature
Engine coolant temperature
521
starboard
531
Oil temperature
Bank 1 exhaust gas
572
temperature sensor
601
Sensor supply voltage A
602
Sensor supply voltage B
603
Sensor supply voltage C
Page 4A-4
Failure
Code
Description
The device, calculation or process detected a
6
fault.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The device, calculation or process detected a
6
fault.
The device, calculation or process detected a
6
fault.
The signal or result is outside the expected
17
range.
Relative to a specified threshold, the value is too
21
low.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
A temperature sensor value is higher than
20
normal.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The input circuit for the sensor is above the valid
24
limit.
The input circuit for the sensor is below the valid
25
limit.
The signal received is valid but is higher than the
4
expected range.
The signal received is valid but is lower than the
5
expected range.
The signal received is valid but is higher than the
4
expected range.
The signal received is valid but is lower than the
5
expected range.
The signal received is valid but is higher than the
4
expected range.
The signal received is valid but is lower than the
5
expected range.
© 2018 Mercury Marine
PCM Fault Name
TPS2_ETC_NoAdapt
MAP_Time_RangeHigh
MAP_Time_RangeLow
MAP_Angle_RangeHigh
MAP_Angle_RangeLow
MAPR_TPS1Rationality
MAPR_TPS2Rationality
BaroRange
OilPress_Low
OilPress_RangeHigh
OilPress_RangeLow
IAT_RangeHigh
IAT_RangeLow
StbdECT_Overtemp
StbdECT_RangeHigh
StbdECT_RangeLow
OilTemp_RangeHigh
OilTemp_RangeLow
EGT_RangeHigh
EGT_RangeLow
XDRPa_RangeHigh
XDRPa_RangeLow
XDRPb_RangeHigh
XDRPb_RangeLow
XDRPc_RangeHigh
XDRPc_RangeLow
90-8M0146617 eng JULY 2018

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V6 200V6 225V8 200V8 225V8 250V8 300

Table of Contents