Altronix eFlowNA8DV Series distribute and switch power to access control systems and accessories. They convert
a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into eight (8) independently controlled 12VDC or
24VDC PTC protected auto-resettable outputs. These power outputs can be converted to dry form "C" contacts.
Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control
System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware
devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe
and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used
to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the
eight (8) outputs.
eFlowNA8DV Series Configuration Reference Chart:
Altronix
Model
Number
9.8-
eFlow4NA8DV
13.2
9.7-
eFlow6NA8DV
13.2
9.7-
eFlow102NA8DV
13.2
eFlow104NA8DV
–
These units are classified as Power-Limited stand alone power supplies with stand-by battery and they are suitable to power:
sensors, electro-mechanical devices (e.g. electric door strikes).
ACM8CB Access Power Controller Module:
• Eight (8) independently trigger controlled outputs. Output options:
a) Eight (8) Fail-Safe filtered power outputs.
b) Eight (8) Fail-Secure filtered power outputs.
c) Any combination of the above.
• Eight (8) Access Control System trigger inputs. Input trigger options:
a) Eight (8) normally open (NO) dry trigger inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
• Eight (8) unswitched filtered aux. power outputs (outputs are rated @ 2.5A).
• Red LEDs on ACM8CB board indicate individual outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
Fire Alarm disconnect input trigger options:
a) Normally open (NO) or normally closed (NC) dry trigger input.
b) Polarity reversal input from FACP signaling circuit.
• Green LED on ACM8CB board indicates FACP disconnect is triggered.
• FACP output relay indicates that FACP input is triggered (form "C" contact rated @ 1A/28VDC).
• Power supply output is factory installed to the ACM8CB board input.
It provides common power for ACM8CB board and all connected access control devices.
• ACM8CB board main fuses are rated @ 10A. Output PTCs are rated @ 2.5A.
eFlowNA8DV Series Installation Guide
Nominal DC Output
Voltage Options
[DC]
[AUX]
19.9-
10.05-
20.2-
26.4
13.2
26.4
19.8-
10.03-
20.19-
26.4
13.2
26.4
10.03-
–
–
13.2
19.8-
20.17-
–
26.4
26.4
Overview:
12VDC 24VDC
3.3A
3.6A
8
5.3A
5.6A
8
9.3A
–
8
–
9.6A
8
Specifications:
5A/
7.5A/
2.1A 2.5A
250V
32V
5A/
10A/
2.1A 2.5A
250V
32V
5A/
15A/
2.1A 2.5A
250V
32V
6.3A/
15A/
2.7A 2.5A
250V
32V
10A/
2.5A/
250V
250V
10A/
2.5A/
250V
250V
10A/
2.5A/
250V
250V
10A/
2.5A/
250V
250V
- 3 -