Automatic Temperature FAN
Enabled / Disabled
Control
AC0 Temperature (°C)
70 / 75 / 80 / 85 / 90 / 95 / 100
5 / 10 / 15 / 20 /25 / 30 / 35 /
AC1 Temperature (°C)
40 / 45 / 50 / 55 / 60 / 65 / 70 /
75 / 80 / 85 / 90 / 95 / 100
Temperature Hysteresis
0 .. 10
Linear Speed change
Enabled / Disabled
FAN Duty Cycle (%) Above AC1 0 .. 100
Speed Change Duration
0 .. 50
FAN PWM Frequency
1 .. 60000
0 .. 100
FAN Duty Cycle
4.3.17.3
Watchdog Configuration submenu
Menu Item
Options
Watchdog Status
Disabled / Enabled
Raise WDT Signals
Event action
Power Button Pulse
System Reset
Reset action
Power Button Override
Raise WDT Signal
Watchdog Delay
0 .. 60
ADLER
ADLER User Manual - Rev. First Edition: 1.0 - Last Edition: 1.2 - Author: A.R./S.B. - Reviewed by M.B. Copyright © 2022 SECO S.p.A.
Disable / Enable Thermal Feed-back FAN Control
Only available when "Automatic Temperature FAN Control"is Enabled
AC0: above this temperature the FAN runs at full speed
Only available when "Automatic Temperature FAN Control" is Enabled.
AC1: below this temperature the FAN is OFF; between AC1 and AC0 the FAN runs at low speed: this never
happens if AC1 is not below AC0.
Only available when "Automatic Temperature FAN Control" is Enabled.
Value added (when temperature is growing) to the ACx thresholds or subtracted from them (when
temperature is decreasing) to avoid oscillations.
Only available when "Automatic Temperature FAN Control" is Enabled.
Linear FAN Duty Cycle growth between AC1 and AC0
Only available when "Automatic Temperature FAN Control" is Enabled and "Linear Speed change" is Disabled
Fan Duty Cycle (%) between AC1 and AC0 (low speed)
Only available when "Automatic Temperature FAN Control" is Enabled and "Linear Speed change" is Disabled
Duration in seconds of linear FAN Speed Change. Allowed range: from 0 to 50.
Only available when "Automatic Temperature FAN Control" is Disabled.
Sets the frequency of the FAN_PWMOUT signal. Typical values are 100 for a 3-wire device and 20000 for
a 4-wire one. Allowed range is 1-60000
Only available when "Automatic Temperature FAN Control" is Disabled.
Default FAN Duty Cycle (%).
Description
Enables or disables the Watchdog Timer. When enabled, the following parameters will appear.
Action executed at the expiring of the Event time-out.
Action executed at the expiring of the reset time-out.
Minutes before watchdog normal operations starts. During delay time-out, a refresh operation will
immediately trigger normal operation.
.