4.3.12 Platform Trust technology submenu
Menu Item
Options
fTPM
Enabled / Disabled
4.3.13 Main Thermal Configuration submenu
Menu Item
Options
Settable Threshold (°C)
Critical Temperature (°C)
[80 .. 110]
Passive Cooling
Settable Threshold (°C)
Temperature (°C)
[60 .. 105]
TC1
[0...16]
TC2
[0..16]
TSP (seconds)
[2..32]
4.3.14 HSUART Transceiver Configuration submenu
Menu Item
Options
RS-232
HSUART #0 Interface
RS-422
RS-485
HSUART #0 RX termination
Disabled / Enabled
HSUART #0 TX termination
Disabled / Enabled
RS-232
HSUART #2 Interface
RS-422
RS-485
HSUART #2 RX termination
Disabled / Enabled
HSUART #2 TX termination
Disabled / Enabled
ADLER
ADLER User Manual - Rev. First Edition: 1.0 - Last Edition: 1.2 - Author: A.R./S.B. - Reviewed by M.B. Copyright © 2022 SECO S.p.A.
Description
Enable/Disable fTPM
Description
Above this threshold, an ACPI aware OS performs a critical shut down. Allowed range is from 80 to 110 included,
where 110 means disabled.
Above this threshold, an ACPI aware OS begins to lower the CPU speed. Allowed range is from 60 to 105 included,
where values not below Critical Temperature mean disabled.
Thermal Constant 1: part of the ACPI Passive Cooling Formula
Thermal Constant 2: part of the ACPI Passive Cooling Formula
Period of temperature sampling when Passive Cooling
Description
Select among RS232 (default), RS-422 or RS-485 interface. When selecting RS-422 or RS-485, the following menu
item will appear
RX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm RX Termination.
TX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm TX Termination.
Select among RS232 (default), RS-422 or RS-485 interface. When selecting RS-422 or RS-485, the following menu
item will appear
RX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm RX Termination.
TX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm TX Termination.