14

OPTION: LIQUID ALARM SENSOR (LA) TYPE LA1S

M&C installs the liquid alarm sensors type LA1S with cable break detection. They are factory calibrated to tap water
and activated with cable break detection. Later purchased liquid alarm sensors must be activated and calibrated.
14.1

ACTIVATING THE LA

A retrofit liquid alarm sensor LA1S must be activated. The LA1S can be activated with or without cable break
detection.
To activate a liquid alarm sensor:
1. Enter the PIN (see chapter "11.2 PIN Entry").
2. Tap and hold the
3. The display shows the code entry.
After activating the LA1S, the sensor needs to be calibrated.
www.mc-techgroup.com
-key for a short moment.
The code for activation is "010".
Confirm the code with the
You can choose between the values "0", "1" and "2". With "1" you activate the
sensor without cable break detection, with "2" you activate the sensor with
cable break detection. With "0" the sensor is deactivated accordingly.
SS5C, SS5C/2, SS5C/3 | 1.00.00
-key.