Camera Interfaces - Quectel Smart Module Series Hardware Design

Table of Contents

Advertisement

A reference design for touch panel interface is shown below.
TP_I2C_SDA
TP_I2C_SCL
TP_RST
TP_INT
Module
Figure 25: Reference Circuit Design for Touch Panel Interface

3.20. Camera Interfaces

Based on standard MIPI CSI input interface, SA800U-WF supports 4 cameras (4-lane + 4-lane + 4-lane +
2-lane), with maximum pixels up to 32 MP. The 2-lane MIPI CSI can only receive data of RAW format. It
can be used for ToF/3D camera modules and cannot be used for display. The video and photo quality are
determined by various factors such as camera sensor, camera lens quality, etc.
Table 23: Pin Definition of Camera Interfaces
Pin Name
LVS1A_1V8
CSI0_CLK_N
CSI0_CLK_P
CSI0_LN0_N
CSI0_LN0_P
CSI0_LN1_N
CSI0_LN1_P
SA800U-WF_Hardware_Design
LDO14A_1V88
R 1
R 2
2. 2K
2. 2 K
D 1
D 2
Pin No.
I/O
Description
J1-149
PO
1.8 V output for IOVDD of cameras
J1-30
AI
MIPI clock of camera 0 (-)
J1-28
AI
MIPI clock of camera 0 (+)
J1-22
AI
MIPI lane 0 data of camera 0 (-)
J1-24
AI
MIPI lane 0 data of camera 0 (+)
J1-16
AI
MIPI lane 1 data of camera 0 (-)
J1-18
AI
MIPI lane 1 data of camera 0 (+)
LDO28A_3V0
D 4
D 3
C 1
C 2
4.7 μF 100 nF
Smart Module Series
SA800U-WF Hardware Design
1
SDA
2
SCL
3
RESET
4
INT
5
GND
6
VDD
D 5
TP
Comment
Vnom = 1.8 V
I
max = 300 mA
O
100 Ω differential
impedance.
68 / 106