Power Output - Quectel Smart Module Series Hardware Design

Table of Contents

Advertisement

If RTC is ineffective, it can be synchronized through network after the module is powered on.
2.5–3.2 V input voltage range and 3.2 V typical value for VRTC, when VBAT is disconnected.
When powered by VBAT, the RTC error is 50 ppm. When powered by VRTC, the RTC error is about
200 ppm.
If rechargeable battery is used, the ESR of battery should be less than 2 kΩ, and it is recommended
to use the MS621FE-FL11E of SEIKO.

3.7. Power Output

SA800U-WF supports output of regulated voltages for peripheral circuits. During application, it is
recommended to use parallel capacitors (33 pF and 10 pF) in the circuit to suppress high-frequency
noise.
Table 5: Power Description
Pin Name
VREG_S4A_1V8
LVS1A_1V8
LVS2A_1V8
LDO12A_1V8
SD_LDO13A
LDO14A_1V88
LDO19A_3V0
SD_LDO21A
LDO24A_3V075
LDO28A_3V0
VREG_BOB
SA800U-WF_Hardware_Design
Default Voltage (V)
1.8
1.8
1.8
1.8
1.8/2.95
1.8
3.0
2.95
3.075
3.0
3.7
SA800U-WF Hardware Design
Drive Current (mA)
2000
300
100
300
50
50
600
800
150
150
2000
Smart Module Series
Comment
Keep
-
Keep
-
-
-
-
-
-
-
Keep