Power On Procedure; Saving The Factory Default - Epson T-B Series Manual

Hide thumbs Also See for T-B Series:
Table of Contents

Advertisement

Installation 3. Power-On

3.3 Power On Procedure

(1) Check the EMERGENCY connector connection.
(2) Connect the TP bypass plug to the TP port.
(3) Connect the power cable to the Manipulator.
(4) Connect the power cable to the power supply socket.
(5) The PROGRAM LED blinks approximately 30 seconds after Controller starts up

3.4 Saving the Factory Default

The manipulator you purchased is set up in the manipulator as the factory default. It is
recommended to save the factory default state of the Controller in case of emergency. For
saving, prepare a USB memory.
For saving the Controller state, refer to "T3-B T6-B Manipulator 8. Memory Port".
8
normally.
If the ERROR LED is turned ON or blinking, check connection in step (1) to (4) and
turn ON the power again.
If the ERROR LED is still ON or blinking, contact the supplier in your region.
(Illustration: T3-B401S)