Use cable clamp on rear side of the Manipulator to fix AC power cable.
3.6.3 Breaker
Install an earth leakage circuit breaker or a circuit breaker in the AC power cable line.
For the rated electric current of the circuit breaker, refer to the following set values.
If you install a circuit breaker, please select one that can handle the "peak current" described
in the following section.
Reference: 3.6.1 Specifications
The power receptacle shall be installed near the equipment and shall be easily accessible.
T-B series Rev.1
T3-B T6-B Manipulator 3. Environments and Installation
Manipulator
T3-B
T6-B
AC Power Cable Clamp
Power
Rated electric current
100VAC
200VAC
100VAC
200VAC
(Illustration: T3-B401S)
10A
5A
20A
10A
55