11.1.3 Checking Latch Release Switch Operation

After connecting the safeguard switch and latch release switch to the EMERGENCY
connector, be sure to check the switch operation for safety by following the procedures
described below before operating the Manipulator.
(1) Turn ON the Manipulator while the safeguard is open in order to boot the controller
(2) Make sure that "Safety" is displayed on the main window status bar.
(3) Close the safeguard, and turn ON the switch connecting to the latch release input.
The information that the safeguard is open can be latched by software based on the latch
release input condition. To cancel the condition, close the safeguard, and then close the
safeguard latch release input.
Open
Closed : The latch release switch does not latch the condition that the safeguard is open.
The latch release input also functions to acknowledge the change of to TEACH mode.
NOTE
In order to change the latched condition of TEACH mode, turn the mode selector key switch
on the Teach Pendant to "Auto". Then, close the latch release input.

11.2 Emergency Stop Switch Connection

11.2.1 Emergency Stop Switch

If it is desired to add an external Emergency Stop switch(es) in addition to the Emergency
Stop on the Teach Pendant and Operator Panel, be sure to connect such Emergency Stop
switch(es) to the Emergency Stop input terminal on the EMERGENCY connector.
The Emergency Stop switch connected must comply with the following and related safety
standard (IEC60947-5-5, etc.):
- It must be a push button switch that is "normally closed".
- A button that does not automatically return or resume.
- The button must be mushroom-shaped and red.
- The button must have a double contact that is "normally closed".
The signal from the Emergency Stop switch is designed to use two redundant circuits.
NOTE
If the signals at the two circuits differ by two seconds or more, the system recognizes it as
a critical error. Therefore, make sure that the Emergency Stop switch has double contacts
and that each circuit connects to the specified pins on the EMERGENCY connector at the
Manipulator. Refer to "11.4 Circuit Diagrams".
Give the emergency stop function to all the equipment which have executable token.
T-B series Rev.1
software.
Make sure that the "Safety" is dimmed on the status bar.
: The latch release switch latches the condition that the safeguard is open.
T3-B T6-B Manipulator 11. EMERGENCY
105