Damper - Komatsu WA250-6 Shop Manual

Wheel loader
Hide thumbs Also See for WA250-6:
Table of Contents

Advertisement

100 Engine and cooling system

Damper

Damper

No.
Check item
Distance between HST pump
1
installation surface and boss tip
Wear on internal teeth of coupling
2
(resin)
3. Coupling
4. Boss
5. HST pump input shaft
6. Cover
7. Flywheel
WA250, 250PZ-6
Criteria
Standard size
75.1
Repair limit: 1.0
Outline
The damper protects the drive systems on and
q
after the engine from torsional vibrations by
reducing the torsional vibrations of the engine
due to the fluctuations in torque.
The power from the engine is transmitted to
q
coupling (3) through flywheel (7), absorbing
torsional vibrations on coupling (3). Then it is
transmitted to HST pump through boss (4).
SEN03825-00
Remedy
Repair limit
Adjust
±0.8
Replace
10-100
1
Unit: mm
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wa250pz-675001

Table of Contents