Settings Related to Scanning
Adjusting the Starting Position for Scanning [Offset Setting/Vertical
magnification Adjustment]
When the output position of the scanned image is not correct or the image appears shortened/elongated
(vertically), adjust the offset and the vertical magnification.
ATTENTION
Normally, you should not have to modify anything as the factory default settings already use adjusted values.
1
Start up the Software Operation Panel.
For details, refer to
2
From the list on the left, select [Device Setting] and click the [Offset] button.
3
Adjust the level of offset/vertical magnification as needed.
Starting Up the Software Operation Panel (page
Scanner Settings (Software Operation Panel)
333).
359