Description Of Parameter Settings - Delta Electronics Elevator Drive VFD-VL User Manual

Elevator drive
Table of Contents

Advertisement

Chapter 4 Parameters|

4.2 Description of Parameter Settings

Group 0 User Parameters
00-00
Identity Code of the AC Motor Drive
Control
VF
VFPG
mode
Settings
00-01
Rated Current Display of the AC Motor Drive
Control
VF
VFPG
mode
Settings
Pr. 00-00 displays the identity code of the AC motor drive. The capacity, rated current, rated
voltage and the max. carrier frequency relate to the identity code. Users can use the following
table to check how the rated current, rated voltage and max. carrier frequency of the AC motor
drive correspond to the identity code.
Pr.00-01 displays the rated current of the AC motor drive. By reading this parameter the user
can check if the AC motor drive is correct.
kW
HP
Pr.00-00
Rated Output Current for General
Purposes (A)
Rated Output Current for Elevators (A)
Max. Carrier Frequency
kW
HP
Pr.00-00
Rated Output Current for General
Purposes (A)
Rated Output Current for Elevators (A)
Max. Carrier Frequency
4-20
: This parameter can be set during operation.
SVC
FOCPG TQCPG FOCPM
Read Only
SVC
FOCPG TQCPG FOCPM
Read Only
5.5
7.5
12
21.9
25
5.5
7.5
7.5
13
12.3
15.8
14
230V Series
7.5
11
10
15
14
16
27.1
41
31
47
15kHz
460V Series
11
15
18.5
10
15
20
25
15
17
19
21
21
27
34
18
24
31
39
15kHz
Factory setting: ##
Factory setting: ##
15
18.5
22
20
25
30
18
20
22
53
70
79
60
80
90
22
30
37
30
40
50
23
25
27
41
60
73
47
75
91
9kHz
Revision Nov. 2008, VLE1, SW V1.03
30
37
40
50
24
26
120
146
150
183
9kHz
45
55
75
60
75
100
29
31
33
91
110
150
113
138
188
6kHz