Pr.07-07 to Pr.07-10 are for heavy load to prevent OV or OC occurs.
Frequency
07-08
Dwell
Frequency
at Accel.
07-11
Fan Control
Control
VF
VFPG
mode
Settings
This parameter is used for the fan control.
When setting to 3, fan will start to run until temperature is less than 40°C if temperature
exceeds 40°C.
07-12
Torque Command
Control
TQCPG
mode
Settings
This parameter is torque command. When Pr.07-14 is 250% and Pr.07-12 is 100%, the actual
torque command = 250X100% X motor rated torque.
07-13
Torque Command Source
Control
TQCPG
mode
Settings
Revision Nov. 2008, VLE1, SW V1.03
07-07
Dwell Tim e
at Accel.
Dwell at accel./decel.
SVC
FOCPG TQCPG FOCPM
0
Fan always ON
1
1 minute after AC motor drive stops, fan will be OFF
2
AC motor drive runs and fan ON, AC motor drive stops and fan OFF
3
Fan ON to run when preliminary heat sink temperature attained
4
Fan always OFF
-100.0 to 100.0% (Pr. 07-14 setting=100%)
0
Digital keypad
1
RS485 serial communication (RJ-11)
2
Analog signal (Pr.03-00)
Chapter 4 Parameters|
07-10
Dwell
07-09
Frequency
Dwell Time
at Decel.
at Decel.
Time
Factory Setting: 2
Unit: 0.1
Factory Setting: 0.0
Factory Setting: 2