Delta Electronics Elevator Drive VFD-VL User Manual page 95

Elevator drive
Table of Contents

Advertisement

Chapter 4 Parameters|
Settings
Disable auto
13
accel./decel. function
14
Reserved
Operation speed
15
command form AUI1
Operation speed
16
command form ACI
Operation speed
17
command form AUI2
18
Emergency Stop
19-23
Reserved
24
FWD JOG command
25
REV JOG command
26
Reserved
27
ASR1/ASR2 selection
Emergency stop (EF1)
28
(Motor coasts to stop)
29-30
Reserved
High torque bias (by
31
Pr.07-21)
Middle torque bias (by
32
Pr.07-22)
Low torque bias (by
33
Pr.07-23)
34-37
Reserved
Disable write EEPROM
38
function
Torque command
39
direction
40
Enable drive function
4-40
Functions
It is used to disable auto accel./decal. function.
When this function is enabled, the source of the
frequency will force to be AUI1.
When this function is enabled, the source of the
frequency will force to be ACI.
When this function is enabled, the source of the
frequency will force to be AUI2.
When this function is enabled, the drive will ramp to stop
by Pr.07-28 setting.
When this function is enabled, the drive will execute
forward Jog command.
When this function is enabled, the drive will execute
reverse Jog command.
ON: speed will be adjusted by ASR 2 setting.
OFF: speed will be adjusted by ASR 1 setting.
When it is ON, the drive will execute emergency stop. (it
will have fault code record)
The high torque bias is according to the Pr.07-21
setting.
The middle torque bias is according to the Pr.07-22
setting.
The low torque bias is according to the Pr.07-23 setting.
When this function is enabled, you can't write into
EEPROM.
When the torque command source is ACI, it can change
torque direction by enabling this function.
When this function is enabled, the drive function can be
executed. This function can be used with multi-function
output (setting Pr.02-11~Pr.02-14 to 15) and (Pr.02-31
and Pr.02-32).
Descriptions
Revision Nov. 2008, VLE1, SW V1.03

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents