Delta Electronics Elevator Drive VFD-VL User Manual page 154

Elevator drive
Table of Contents

Advertisement

It is helpful for the stable control by inputting correct pulse type.
10-03
Encoder Feedback Fault Treatment (PGF1, PGF2)
Control
VFPG
FOCPG TQCPG
mode
Settings
10-04
Detection Time for Encoder Feedback Fault
Control
VFPG
FOCPG TQCPG FOCPM
mode
Settings
When PG loss, encoder signal error, pulse signal setting error or signal error, if time exceeds
the detection time for encoder feedback fault (Pr.10-04), the PG signal error will occur. Refer
to the Pr.10-03 for encoder feedback fault treatment.
10-05
Encoder Stall Level (PGF5)
Control
VFPG
SVC
mode
Settings
This parameter determines the maximum encoder feedback signal allowed before a fault
occurs. (max. output frequency Pr.01-00 =100%)
10-06
Encoder Stall Detection Time
Control
VFPG
SVC
mode
Settings
10-07
Encoder Slip Range (PGF7)
Control
VFPG
SVC
mode
Settings
Revision Nov. 2008, VLE1, SW V1.03
Single-phase input
5
0
Warn and keep operation
1
Warn and RAMP to stop
2
Warn and stop operation
0.0 to 10.0 sec
FOCPG FOCPM
0 to 120% (0: disable)
FOCPG FOCPM
0.0 to 2.0 sec
FOCPG FOCPM
0 to 50% (0: disable)
For war d
running
A
Chapter 4 Parameters|
Factory Setting: 2
Factory Setting: 1.0
Factory Setting: 115
Factory Setting: 0.1
Factory Setting: 50
Unit: 0.1
Unit: 1
Unit: 0.1
Unit: 1
4-99