Description Of Parameter Settings; Group 0: User Parameters - Delta Electronics VFD S 115V Series User Manual

Compact low-cost easy-to-use general-purpose ac motor drives
Table of Contents

Advertisement

5.3 Description of Parameter Settings

Group 0: User Parameters

0-00
Identity Code of the AC Motor Drive
Settings
0-01
Rated Current Display of the AC motor drive
Settings
Pr. 0-00 displays the identity code of the AC motor drive. The capacity, rated current, rated
voltage and the max. carrier frequency relate to the identity code. Users can use the following
table to check how the rated current, rated voltage and max. carrier frequency of the AC
motor drive correspond to the identity code.
Pr. 0-01 displays the rated current of the AC motor drive. By reading this parameter the user
can check if the AC motor drive is correct.
Pr.0-00
Rated Output Current (A)
Max. Carrier Frequency
Pr.0-00
Rated Output Current (A)
Max. Carrier Frequency
0-02
Parameter Reset
Settings d9
d10
This setting allows the user to return all parameters to the factory default settings.
Start-up Display Selection
0-03
Settings d0
d1
Revision August 2008, SE09, SW V2.61
Read Only
Read Only
115V/230V Series
kW
0.2
HP
0.25
d0
1.6
kW
0.4
HP
0.5
1.5
All parameters are reset to factory settings (50Hz, 220V/380V)
All parameters are reset to factory settings (60Hz, 220V/440V)
Display the frequency command value (LED F)
Display the actual output frequency (LED H)
This parameter can be set during operation.
0.4
0.75
0.5
d2
2.5
10kHz
460V Series
0.75
1.0
d3
d5
2.5
10kHz
Chapter 5 Parameters|VFD-S Series
Factory setting: d#
Factory setting: d ##.#
1.5
1.0
2.0
d4
d6
4.2
7.5
1.5
2.0
d7
4.2
Factory Setting: d0
Factory Setting: d0
2.2
3.0
d8
11.0
2.2
3.0
d9
5.5
5-17