Delta Electronics Elevator Drive VFD-VL User Manual page 79

Elevator drive
Table of Contents

Advertisement

Chapter 4 Parameters|
RA: Pr.02-11 is set to 9 (Drive ready).
After applying the power to the AC motor drive, if there is no other abnormal status, the
contact will be ON. At the meanwhile, if Pr.00-04 is set to 15 or 18, it will display 0001 with
LED U is ON on the keypad. The setting 15 is the status of digital output and the setting 18 is
the corresponding CPU pin status of digital output. User can set 15 to monitor the digital
output status and then set to 18 to check if the wire if normal.
00-05
User Defined Coefficient K
Control
VF
VFPG
mode
Settings
It is used digital setting method
Digital 4: decimal point number (0: no decimal point, 1: 1 decimal point and so on.)
Digit 0-3: 40 to 9999 (the corresponding value for the max. frequency).
For example, if use uses rpm to display the motor speed and the corresponding value to the 4-
pole motor 60Hz is 1800. This parameter can be set to 01800 to indicate that the
corresponding value for 60Hz is 1800rpm. If the unit is rps, it can be set 10300 to indicate the
corresponding value for 60Hz is 30.0 (a decimal point).
Only frequency setting can be displayed by the corresponding value.
After setting Pr.00-05, it won't display the unit of frequency "Hz" after returning to the main
menu.
00-06
Software Version
Control
VF
VFPG
mode
Settings
Display
4-24
SVC
FOCPG TQCPG FOCPM
Digit 4: decimal point number (0 to 3)
Digit 0-3: 40 to 9999
Us
e
r
E
C
o e
S
E
EE
E
E0
SVC
FOCPG TQCPG FOCPM
Read Only
#.##
f
f i i
c
e n
t
0
0 0
0
E
EE
E
cor re spo nd in g va lu e
de cima l p oi nt n umb er
Revision Nov. 2008, VLE1, SW V1.03
Factory setting: 0
Factory setting: Read Only