Delta Electronics Elevator Drive VFD-VL User Manual page 93

Elevator drive
Table of Contents

Advertisement

Chapter 4 Parameters|
02-02
Multi-Function Input Command 2 (MI2)
02-03
Multi-Function Input Command 3 (MI3)
02-04
Multi-Function Input Command 4 (MI4)
02-05
Multi-Function Input Command 5 (MI5)
02-06
Multi-Function Input Command 6 (MI6)
02-07
Multi-Function Input Command 7 (MI7)
Multi-Function Input Command 8 (MI8)
02-08
(specific terminal for Enable)
Settings
0: no function
1: multi-step speed command 1
2: multi-step speed command 2
3: multi-step speed command 3
4: multi-step speed command 4
5: Reset
6: JOG command
7: acceleration/deceleration speed inhibit
8: the 1st, 2nd acceleration/deceleration time selection
9: the 3rd, 4th acceleration/deceleration time selection
10: EF input (07-28)
11: Reserved
12: Stop output
13: Disable auto accel./decel. function
14: Reserved
15: operation speed command form AUI1
16: operation speed command form ACI
17: operation speed command form AUI2
18: Emergency Stop (07-28)
19-23: Reserved
24: FWD JOG command
25: REV JOG command
26: Reserved
27: ASR1/ASR2 selection
28: Emergency stop (EF1) (Motor coasts to stop)
29-30: Reserved
31: High torque bias (by Pr.07-21)
4-38
0-43
Settings
Control Mode
VF
VFPG
SVC
Revision Nov. 2008, VLE1, SW V1.03
Factory Setting: 2
Factory Setting: 3
Factory Setting: 4
Factory Setting: 0
Factory Setting: 0
Factory Setting: 0
Factory Setting: 0
FOCPG TQCPG FOCPM