Delta Electronics Elevator Drive VFD-VL User Manual page 88

Elevator drive
Table of Contents

Advertisement

01-22
JOG Frequency
Control
VF
VFPG
mode
Settings
Both external terminal JOG and key "JOG" on the keypad can be used. When the jog
command is ON, the AC motor drive will accelerate from 0Hz to jog frequency (Pr.01-22).
When the jog command is OFF, the AC motor drive will decelerate from Jog Frequency to zero.
The used Accel./Decel. time is set by the Jog Accel./Decel. time (Pr.01-20, Pr.01-21).
The JOG command can't be executed when the AC motor drive is running. In the same way,
when the JOG command is executing, other operation commands are invalid except
forward/reverse commands and STOP key on the digital keypad.
01-22
JO G fr equency
01-07
4th output
frequency
setting
01-23
Switch Frequency between 1st/4th Accel/decel
Control
VF
VFPG
mode
Settings
Revision Nov. 2008, VLE1, SW V1.03
Frequency
01-00
Max. O utput
Frequency
Frequency
Setting
accel. time
01-12,14,16,18
SVC
FOCPG TQCPG FOCPM
0.00~120.00Hz
F requenc y
01-20
JO G ac celeration time
JO G ac cel./dec el . time
SVC
FOCPG FOCPM
0.00~120.00Hz
decel. time
01-13,15,17,19
Accel./Decel. Time
JO G dec el er ation time
Chapter 4 Parameters|
Time
Factory setting: 6.00
01-21
Time
Factory setting: 0.00
Unit: 0.01
Unit: 0.01
4-33