Chapter 4 Parameters|
02-10
Digital Input Operation Direction
Control
VF
VFPG
mode
Settings
This parameter is used to set the input signal level and it won't be affected by the
SINK/SOURCE status.
Bit0 is for FWD terminal, bit1 is for REV terminal and bit2 to bit9 is for MI1 to MI8.
User can change terminal status by communicating.
For example, MI1 is set to 1 (multi-step speed command 1), MI2 is set to 2 (multi-step speed
command 2). Then the forward + 2
need to set Pr.02-10=9 by communication and it can forward with 2
need to wire any multi-function terminal.
bit9 bit8 bit7 bit6 bit5 bit4
MI8 MI7 MI6 MI5 MI4 MI3
02-11
Multi-function Output 1 RA, RB, RC (Relay1)
02-12
Multi-function Output 2 MRA, MRC (Relay2)
02-13
Multi-function Output 3 (MO1)
02-14
Multi-function Output 4 (MO2)
02-15
Multi-function Output 5 (MO3) (need to use with EMVL-IODA01)
02-16
Multi-function Output 6 (MO4) (need to use with EMVL-IODA01)
02-17
Multi-function Output 7 (MO5) (need to use with EMVL-IODA01)
02-18
Multi-function Output 8 (MO6) (need to use with EMVL-IODA01)
02-19
Multi-function Output 9 (MO7) (need to use with EMVL-IODA01)
02-20
Multi-function Output 10 (MO8) (need to use with EMVL-IODA01)
02-21
Multi-function Output 11 (MO9) (need to use with EMVL-IODA01)
02-22
Multi-function Output 12 (MO10) (need to use with EMVL-IODA01)
Settings
0: No function
1: Operation indication
4-42
SVC
FOCPG TQCPG FOCPM
0 ~ 65535
nd
bit3
MI2
0-41
Settings
step speed command=1001(binary)=9 (Decimal). Only
bit2 bit1 bit0
MI1 REV FWD
VF
VFPG
Factory setting: 0
nd
step speed. It doesn't
Factory Setting: 11
Factory Setting: 1
Factory Setting: 0
Control Mode
SVC
FOCPG
Revision Nov. 2008, VLE1, SW V1.03
Unit: 1
TQCPG
FOCPM