0: Output frequency (Hz)
1: Frequency command (Hz)
2: Motor speed (RPM)
3: Output current (rms)
4: Output voltage
5: DC Bus Voltage
6: Power factor
7: Power
8: Output torque
9: AUI1
10: ACI
11: AUI2
12: q-axis current
13: q-axis feedback value
14: d-axis current
15: d-axis feedback value
16: q-axis voltage
17: d-axis voltage
18: Torque command
19-20: Reserved
03-18
Analog Output Gain 1
03-21
Analog Output Gain 2
Control
VF
VFPG
mode
Settings
This parameter is set the corresponding voltage of the analog output 0.
03-19
Analog Output Value in REV Direction 1
03-22
Analog Output Value in REV Direction 2
Control
VF
VFPG
mode
Settings
Revision Nov. 2008, VLE1, SW V1.03
Settings
SVC
FOCPG TQCPG FOCPM
0 to 200.0%
SVC
FOCPG TQCPG FOCPM
0
Absolute value in REV direction
1
Output 0V in REV direction
2
Enable output voltage in REV direction
10V
frequency
03-19=0
0V
Selection for the analog output direction
VF
VFPG
10V
frequency
03-19=1
0V
Chapter 4 Parameters|
Control Mode
SVC
FOCPG TQCPG FOCPM
Factory setting: 100.0
Factory setting: 0
10V
frequency
03-19=2
0V
Unit: 0.1
Unit: 0.1