Chapter 4 Parameters|
Group 11 Advanced Parameters
11-00
System Control
Control
FOCPG FOCPM
mode
Settings
Bit 0=1: PDFF function is enabled and system will generate an ASR setting, Pr. 10-11~10-16
will be invalid and Pr.11-09 to 11-10 will be valid.
Adjust by r equir ement Pr.10-17
(A SR1/ASR2 s wi tc h frequency)
Pr.10- 20: Zer o speed/ASR1 width adjustment
Pr.10- 21: ASR 1/ASR2 width adjustment
Adjust by r equir ement Pr.07-25~28 (torque li mit)
4-104
Bit 0=0
No function
Bit 0=1
ASR Auto tuning, PDFF enable
Bit 7=0
No function
When position control is enabled, it doesn't need to set Pr.07-02
Bit 7=1
(DC Brake Current Level)
when power is applied, it will detect the position of magnetic field
Bit 15=0
again
when power is applied, it will start from the magnetic field
Bit 15=1
position of previous power failure
Whe n Pr.11- 00
is se t B it 0=1
YES
Setting auto gain adjustment
Pr.11-00=1
Adjust Pr.11- 06, 11- 07 and 11- 08
separately by s peed response
Adjust by r equir ement
Pr.11-09, Pr. 11-10 (PDFF function)
N O
Adjust gain value by manual
Pr.11-00=0 ( fac tor y s etting)
Adjust Pr.10-11, 10- 12, 10- 13,
10-14, 10-15 and 10-16
separately by s peed response
Adjust by r equir ement
Pr.10- 18 (for general,
no need to adjus t)
Revision Nov. 2008, VLE1, SW V1.03
Factory Setting: 0