Delta Electronics Elevator Drive VFD-VL User Manual page 90

Elevator drive
Table of Contents

Advertisement

01-29
Switch Frequency for S3/S4 Changes to S5
Control
VF
VFPG
mode
Settings
It is used to set the switch frequency between S4 and S5 for smooth stop.
It is recommended to set this parameter to the leveling speed of elevator.
F requenc y
01-12
accel. time
01-24=S1
01-28
Mode Selection when Frequency< Fmin
Control
VF
VFPG
mode
Settings
When the AC motor drive is at 0Hz, it will operate by this parameter.
When it is set to 1 or 2, voltage will be output by Fmin corresponding output voltage.
Deceleration Time when Operating without RUN
01-31
Command
Control
VF
VFPG
mode
Settings
Revision Nov. 2008, VLE1, SW V1.03
Frequency
01-25
01-24
SVC
FOCPG FOCPM
0.00~120.00Hz
01-25=S2
SVC
0
Output Waiting
1
Zero-speed operation
2
Fmin (4th output frequency setting)
SVC
FOCPG FOCPM
0.00~600.00 Sec
01-26
01-27
01-26=S3
01-13
decel. time
01-27=S4
01-30=S5
Chapter 4 Parameters|
Time
Factory setting: 0.00
01-29
Switch fr equency
for S3/S 4 changes
to S5
Time
Factory setting: 0
Factory setting: 2.00
Unit: 0.01
Unit: 0.01
4-35