FIELD OPERATION
ERROR REPORTS
Error ref.
11
12
13
14
15
16
17
18
21
22
23
24
25
31
32
33
35
36
4-12
Failure or interruption of the solenoid to raise the header
Failure or interruption of the solenoid to lower the header
Short circuit in the stubble height and compensation control wiring loom
Interruption of the stubble height and compensation control wiring loom
Failure or interruption of header height control switch
No power supply to the control switches
Battery voltage higher than 18 V
Failure of selector switch 17
Failure of wiring loom to the header height sensor
Incorrect stubble height signal
Failure or interruption of the header cylinder pressure sensor
Incorrect pressure sensor signal
Failure of header height control switch
- section ''Slow'' or ''Fast'': OK
- section ''Lower'' or ''Raise'': NOT OK
No signal or incorrect signal from left-hand autofloat sensor [accessory]
No signal or incorrect signal from right-hand autofloat sensor [accessory]
Failure of automatic header height control switch 20 wiring loom
Battery voltage lower than 12 V
Failure of the hydraulic header height control valve (electrical control: OK)
Description