PAPER TRANSPORT, FUSING, AND PAPER EXIT SECTIONS
6.9.14 CAUTIONS TO BE TAKEN WHEN USING A FUSING UNIT
THAT HAS BEEN IN STOCK FOR A LONG PERIOD
NOTE: When using a fusing unit that has been in stock for an extended period,
press the pump with your fingers to check whether an adequate amount of
oil is pumped up.
Reason: A fusing unit that has been stocked unused for a long time may
have a clogged pump or valve in the oil supply unit. Such a fusing unit will
not run smoothly. This may result in an oil supply shortage and the hot
roller will fail earlier than normal.
6-76
24 February, 1999