COVERS, FANS, AND FILTERS

6.1.5 EXPOSURE GLASS

1. Remove the vertical scale [A] (2 screws).
2. Remove the horizontal scale [B] (3 screws).
3. Remove the exposure glass [C].
NOTE: When reinstalling the exposure glass, ensure that the white plate faces
down and to the left.

6.1.6 OPERATION PANEL

– A258 only –
1. Remove the operation panel [H] (2 screws and 1 connector).
– A259/A260 only –
1. Remove the operation panel [D] (2 screws, 2 grounding wires, and 3
connectors).
NOTE: Perform the touch panel calibration procedure after replacing the
operation panel (see "Touch Panel Calibration").

6.1.7 UPPER COVERS

1. Remove the upper right cover [E] (1 screw).
2. Remove the upper left cover [F] (1 screw).
3. Remove the upper rear cover [G] (1 screw).
[A]
[F]
[D]
[H]
A259R905.WMF
6-4
24 February, 1999
[G]
[B]
[C]
[E]