Standards; Used Standards; Ce Marking; Declaration Of Conformity - Bosch Rexroth IndraControl VDP 92.3 Project Planning Manual

Machine operator panel
Table of Contents

Advertisement

16/52
Bosch Rexroth AG | Electric Drives
Technical Data
Air pressure
Mechanical strength
4.4

Standards

4.4.1

Used Standards

EN Standards
4.4.2

CE Marking

Declaration of Conformity

and Controls
In operation
Up to 2 000 m above MSL according to DIN 60204
Max. vibration:
Frequency range: 10-150 Hz
Excursion: 0.075 mm for 10-57 Hz
Acceleration: 1 g for 57-150 Hz
According to EN 60068-2-6
Fig.4-2:
Ambient conditions
The system components of the displays correspond to the following standards:
Standard
EN 60 204-1
EN 50 081-2
EN 50 082-2
EN 60 742
EN 60 950
EN 61 131
EN 61 131-2
EN 418
EN 60 529
EN 60 068-2-6
EN 60068-2-27
Fig.4-3:
Used standards
The electronic products described in the project planning manual comply with
the requirements and goals of the following EC guideline and with the agreed
European standards:
EMC guideline 2004/108/EC
The electronic products described in the project planning manual comply with
the requirements on the operation within the industrial environment:
Rexroth IndraControl VDP 92.3 | Project Planning Manual
Storage / Transport
Max. shock: 15 g according to DIN
IEC 68-2-27, function not disturbed
Meaning
Electrical equipment of machines
Basic technical standard, noise immunity (industrial en‐
vironment)
Basic technical standard, emitted interference (industrial
environment)
Transformer for 24 V power supply unit, protective sepa‐
ration
Overvoltage category II
Requirements regarding the 24V outputs
Requirements on the 24 power supply
Machine safety, EMERGENCY STOP devices
Degrees of protection (incl. housings and installation
compartments)
Vibration test
Shock test