3.3-3 Base control console

This control console is located in the panel mounted
in the control compartment. It has the following
controls:
Hourmeter - This gauge records accumulated
1
operating time of engine.
Circuit breakers - In the event of a power
2
overload or positive circuit grounding, the circuit
breaker pops out. Push breaker back in to reset.
Platform rotation switch - This switch controls
3
left or right rotation of platform.
Turret rotation switch - This switch controls left
4
or right rotation of turret.
Platform leveling override switch - This switch
5
overrides automatic leveling of platform and
controls tilting up or tilting down of platform.
7
Jib up/down switch - This switch controls up or
6
down movement of jib.
213217AAA
24
2
1
18
HOUR METER
QUARTZ
17
TM
16
15
14
13
12
Figure 08 Base control console
3
4
5
6
7
8
11
10
9
7
Fly boom extend/retract switch - This switch
7
controls extension or retraction of fly boom.
7
Main boom raise/lower switch - This switch
8
controls raising or lowering of main boom.
Emergency stop button - This red "mushroom-
9
head" pushbutton disconnects power to control
circuit and shuts engine off.
7
Riser raise/lower switch - This switch controls
1 0
raising or lowering of riser.
7
Positive air shutoff switch (if equipped) -
1 1
This switch allows the operator to shut off the
air supply to the engine if the engine continues
running after the main power is shut down.
7
Status indicator pilot lights - These lights
1 2
indicate operational status and errors in any