Section 3 – Familiarization
3.5-7 Elevate telematics - access control
unit (if equipped)
Access control is an added functionality of the Elevate
Trackunit which can be used in Skyjack vertical masts,
scissor lifts, booms or telehandlers.
The access control functionality DOES NOT affect
any of the following: emergency lowering, secondary
guarding electrical (if equipped), load sensing (if
equipped), and horn. These functions will always
remain available. The access control unit prevents the
engine from starting without an authorized code or
card.
IMPORTANT
It is the owner's responsibility to provide unique
PIN codes or smart ID cards for machines
equipped with access control functionality. Skyjack
DOES NOT provide or reset PIN codes or smart ID
cards. If the PIN code or smart ID card does not
work or has been lost, contact the owner of the
machine for assistance.
Access control functionality enables the user to
control access to machine operation. The user may
be provided with unique PIN codes or smart ID cards
that they need to use to unlock and activate the
machine. An ElevateTelematics device and an access
control keypad are required to have this functionality.
Access control to the MEWP may be customized
by the machine owner using the Trackunit manager
(https://www.trackunit.com/services/manager/).
If PIN code or smart ID card has not been provided or
does not work, contact the machine owner.
NOTE
It is the owner's responsibility to provide unique
PIN codes or smart ID cards if machines are
equipped with this functionality. Skyjack DOES
NOT provide or reset PIN codes or smart ID
cards.
213217AAA
36
Optional Equipment and Attachments
If the MEWP is equipped with the access control
functionality, it will require an access PIN code or
smart ID card to be operated.
1
Figure 23 Access control unit keypad
Orange indicator light: This light indicates that
1
the access control unit is ON. The keypad is
always powered regardless of emergency stop,
key switch, or main power disconnect position.
Green indicator light: This light indicates that
2
the access control unit is active.
Red indicator light - This light flashes when a
cancel input has been received from the keypad.
Operation
To permit operation of the machine, the green light on
the access control unit keypad must be ON and the
main power disconnect switch, the base emergency
stop, and the base key switch must all be in the
ON position. The access control unit is enabled by
entering the unique PIN code followed by the green
checkmark, or tapping the smart ID card. Unless
activated prior to enabling the access control unit, the
main power disconnect, base emergency stop and
base key switch all must be in the ON position within
the time set by the machine owner for access control
operation.