10 Technical data

10.4 Digital inputs

Digital input 1
Digital input 2

10.5 Digital output

Relay (changeover contact)
without contact protection
circuit
Optocoupler output

10.6 General specifications

Circuit variants
Operating modes
Subordinate control loop
Current limiting
Load monitoring
R control
SiC reserve
Analog output
Control accuracy
Electrical connection
Semiconductor fuse
Protection type
Protection rating
Admissible ambient temperature range
Admissible storage temperature range
Cooling
Resistance to climatic conditions
Installation position
Operating conditions
Altitude
Electromagnetic
compatibility
Test voltage
Creepage distances
88
For connection to PLC level
30000 switching operations at a switching capacity of AC 230V/3 A(1.5 A)
50 Hz
I
= 2 mA, U
Cmax
CEOmax
Type 709051-X-XX-70 and 100
2
U-,U
-, I- , I
In operation, the load current can be configured in the range of 10 to 100 % I
This limits the effective value of the load current.
Detection of partial load failure or load short circuit
Setting range from R
Message indicating when the voltage reserve for SiC heating rods is exhausted
Standard signal 0/4 to 20 mA, 0/2 to 10 V or 0/1 to 5 V
The regulation will eliminate voltage supply variations within the tolerance range
(+15 %/ -20 %) with an accuracy of ± 0.5 %
Control cables via pluggable screw terminals for conductor cross sections
in power section screw terminals
2
10 mm
to 50 mm
2
The I
t value (operating integral) of the fuses integrated into the device must be less than
Protection rating I, with isolated control circuitry for connection to SELV circuits
-10 to +70°C (1K3 according to EN 60 721-3-1)
forced convection, maximum inlet air temperature 35°C
rel. humidity
5 to 85 % annual average, without condensation 3K3 according to
EN 60 721
The power controller is designed as a built-in device according to: EN 50178,
pollution degree 2, overvoltage category Ü III
Interference emission: class A - only for industrial use. Interference immunity: industrial re-
Control electronics to load circuit ≥ 5.5 mm, control electronics to housing ≥ 5.5 mm, de-
SELV = Separate Extra Low Voltage (safe low voltage)
= 32 V
Type 709051-X-XX-200
Single-phase operation
Amplitude control
2
- and P control configurable as a standard feature
panel.
to 10x R
, R
= nominal voltage / nominal current
Nom
Nom
Nom
Output value configurable
0.5 to 2.5 mm
in power section screw terminals U, PE. N(V) :
2
Screw terminals C, D 1D, 1C: 30 mm
2
20000 A
s.
IP 20 according to EN 60529
5 to 40°C (3K3 according to EN 60 721-3-3)
Vertical
≤ 2000 m above MSL
according to DIN 61326
quirements
According to EN 50178
vice can be connected to SELV circuits.
V1.00/EN/00741192/2021-03-30 [IPC 300]
on the front
N
2
2
2
10 mm
to 50 mm
2
to 95 mm
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

709051

Table of Contents