MASTERTIG COOLER M
Feature
Connection voltage
Maximum rated supply current
Rated cooling power at 1 l/min
Cooling power at 1.6 l/min
Recommended coolant
Coolant pressure (max)
Tank volume
Operating temperature range *
Storage temperature range
EMC class
Degree of protection **
External dimensions
Weight without accessories
Standards
* With recommended coolant
** When mounted
© Kemppi
Description
Value
U
50/60 Hz
220...460 V AC, 1~/3~
1
1.0 A
I
1max
0.9 kW
1.0 kW
MPG 4456 (Kemppi mixture)
0.4 MPa
3.0 l
-20 ... +40 °C
-20 ... +60 °C
A
IP23S
615 x 206 x 268 mm
L x W x H
12.5 kg
IEC 60974-2
IEC 60974-10
64/73
MasterTig 235ACDC, 325DC, 335ACDC
Operating manual - EN
1920900 / 1921