IE850A
Applied voltage:
3.3
Connecting the Target System
Confirm that the IE850A main unit and the target system are turned off, and connect the IE850A main
unit to the target system via the trace cable for the IE850A as shown below.
Press the spring latches on both sides of the target-side connector of the cable when inserting or
removing the trace cable for the IE850A.
When the target system is the emulation adapter, also connect the power-supply cable for the
emulation adapter.
Connecting the connector:
R20UT4461EJ0110 Rev. 1.10
Apr.22.19
The IE850A supplies 5.5 V when it is supplying power to the emulation adapter.
Confirm the direction with the notch on the connector and connect the emulator while
taking care that the direction of insertion is correct.
CAUTION
CAUTION
Setup Procedure
Page 23 of 40