2. 6 Connecting QB-78F1026 to Target System

If connecting the emulation probe (QB-80-EP-01T), connect it to the QB-78F1026 and the target system by the following
procedure.
(a) Connection of emulation probe to the QB-78F1026
Connect the emulation probe to the QB-78F1026, as shown below.
(b) Connection of emulation probe GND wire
There are two GND wires in the emulation probe. Connect them to the QB-78F1026 and target system.
<1> Fasten the GND wire on the QB-78F1026 side of the emulation probe to the nut on the bottom of
the QB-78F1026 using a #0 or #1 Phillips precision driver (connection of B to A in Figure 2-6).
<2> Next plug the connector on top of the emulation probe into the connector at the opening on the
bottom of the QB-78F1026 from below being careful of the insertion direction.
C
Target system
R20UT0290JJ0100 Rev. 1.00
Sep 30, 2010
Figure 2-5. Connection of emulation probe to the QB-78F1026
Insert CN1 and CN2 of the probe into
TCN1 and TCN2 of the QB-78F1026.
Figure 2-6. GND Wire