2.5 Connecting QB-RL78G1C to Target System

If connecting the emulation probe (QB-80-EP-01T), connect it to the QB-RL78G1C and the target system by the
following procedure.
(a) Connect the QB-RL78G1C to the probe.
Connect the emulation probe to the QB-RL78G1C, as shown below.
Insert CN1 and CN2 of the probe into TCN1 and TCN3 of the QB-RL78G1C.
(b) Connection of emulation probe GND wire
There are three GND wires in the emulation probe. Connect them to the QB-RL78G1C and target system.
<1> Fasten the GND wire on the QB-RL78G1C side of the emulation probe to the nut on the bottom of
the QB-RL78G1C using a #0 or #1 Phillips precision screwdriver (connection of B to A in Figure 2-8).
<2> Next insert the connector on the top of the emulation probe into the connector at the opening on
the bottom of the QB-RL78G1C from below being careful of the insertion direction.
R20UT2079EJ0100 Rev.1.00
2013.07.12
Figure 2-10. Connect the QB-RL78G1C to the probe
QB-80-EP-01T
Figure 2-11. GND Wire