Connecting Qb-Rl78G1F To Target System - Renesas QB-RL78G1F User Manual

In-circuit emulator
Table of Contents

Advertisement

QB-RL78G1F In-Circuit Emulator

2.5 Connecting QB-RL78G1F to Target System

If connecting the emulation probe (QB-80-EP-01T), connect it to the QB-RL78G1F and the target system by the
following procedure.
(a) Connect the QB-RL78G1F to the probe.
Connect the emulation probe to the QB-RL78G1F as shown below.
Insert CN1 and CN2 of the probe into TCN1 and TCN3 of the QB-RL78G1F.
Insert the probe holder into QB-RL78G1F as below.
(b) Connection of emulation probe GND wire
There are three GND wires in the emulation probe. Connect them to the QB-RL78G1F and target system.
<1> Fasten the GND wire on the QB-RL78G1F side of the emulation probe to the nut on the bottom of
the QB-RL78G1F using a #0 or #1 Phillips precision screwdriver (connection of B to A in Figure 2-8).
<2> Next insert the connector on the top of the emulation probe into the connector at the opening on
the bottom of the QB-RL78G1F from below being careful of the insertion direction.
R20UT3352EJ0100 Rev.1.00
Jan 30, 2015
Figure 2-7. Connect the QB-RL78G1F to the probe
Figure 2-8. GND Wire
CHAPTER 2 SETUP PROCEDURE
QB-RL78G1F
Page 29 of 41