QB-78K0FX2L In-Circuit Emulator

2.4 Connecting QB-78K0FX2L to Target System

If connecting the emulation probe (QB-80-EP-01T/QB-144EP-02S), connect it to the QB-78K0FX2L and the target
system by the following procedure.
(a) Connect the QB-78K0FX2L to the probe.
Connect the emulation probe to the QB-78K0FX2L, as shown below.
Insert CN1 and CN2 of the probe into TCN1 and TCN3 of the QB-78K0FX2L.
(b) Connection of emulation probe GND wire
There are three GND wires in the emulation probe. Connect them to the QB-78K0FX2L and target system.
<1> Fasten the GND wire on the QB-78K0FX2L side of the emulation probe to the nut on the bottom of
the QB-78K0FX2L using a #0 or #1 Phillips precision screwdriver (connection of B to A in Figure 2-6).
<2> Next insert the connector on the top of the emulation probe into the connector at the opening on
the bottom of the QB-78K0FX2L from below being careful of the insertion direction.
R20UT2057EJ0100 Rev.1.00
2012.05.18
Figure 2-5. Connect the QB-78K0FX2L to the probe.
Insert CN1 and CN2 of the emulation probe into TCN1,
Figure 2-6. GND Wire
CHAPTER 2 SETUP PROCEDURE
TCN2 of the QB-78K0RFX3.
QB-78K0FX2L