Connecting Qb-Rl78D1A2 To Target System - Renesas QB-RL78D1A2 User Manual

In-circuit emulator
Table of Contents

Advertisement

QB-RL78D1A2 In-Circuit Emulator

2.4 Connecting QB-RL78D1A2 to Target System

If connecting the emulation probe (QB-144-EP-02S), connect it to the QB-RL78D1A2 and the target system by the
following procedure.
(a) Connect the QB-RL78D1A2 to the probe.
Connect the emulation probe to the QB-RL78D1A2, as shown below.
Insert CN1, CN2 and CN3 of the probe into TCN1, TCN2 and TCN3 of the QB-RL78D1A2.
Insert the probe holder into QB-RL78D1A2 as below.
(b) Connection of emulation probe GND wire
There are three GND wires in the emulation probe. Connect them to the QB-RL78D1A2 and target system.
<1> Fasten the GND wire on the QB-RL78D1A2 side of the emulation probe to the nut on the bottom
of the QB-RL78D1A2 using a #0 or #1 Phillips precision screwdriver (connection of B to A in Figure
2-6).
<2> Next insert the connector on the top of the emulation probe into the connector at the opening on
the bottom of the QB-RL78D1A2 from below being careful of the insertion direction (connection of C
in Figure 2-6 to QB-RL78D1A2).
R20UT3110EJ0101 Rev.1.01
Nov 28, 2014
Figure 2-5. Connect the QB-RL78D1A2 to the probe
Probe holder
CHAPTER 2 SETUP PROCEDURE
Page 26 of 41