Control Interlock Replacement - Toro Power TRX Commercial 1428 Service Manual

Table of Contents

Advertisement

QUICK STICK® Installation

Control Interlock Replacement

Control Interlock Removal
Controls: Service and Repairs
Note: The cable clamp must be installed on the chute control rod or the
cable latch will not function.
1. Install the QUICK STICK® onto the control panel. Secure with 3 (1/4–20 x 1
inch) carriage bolts and nuts on the chute control rod.
2. Install the front cover into position. Secure with the latch tabs on the rear.
3. Install the 2 (1/4–10 x 0.82 inch) screws securing the QUICK STICK® cover
in place on the underside of the control panel.
4. Hook the Z-bend and connect the deflector cable from the underside.
1. Park the machine on a level surface. Stop the engine, wait for all moving
parts to stop and remove the key.
2. Disconnect the auger and traction cables from the levers. If this is a wheel
clutch model, disconnect the wheel clutch cables.
g263048
3. Remove the shoulder screw under the RH handgrip. When removed, the
lockout latch, extension spring, flat washer, and locknut will drop out.
Figure 45
Page 6–10
POWER TRX™ HD Service Manual
3440-740 Rev A