Track Installation (continued)
Hydro Replacement
Hydro Removal
Track Drive System: Service and Repairs
RH side of the machine. If a deflection of 9.5 mm (3/8 inch) is not achieved,
see the Operator's Manual for the deflection setting procedure.
g332810
3. Torque the 2 (9/16 inch) nuts on the LH bogey yolk to 47.5 N• m (35 ft-lb).
Repeat on the RH side of the machine.
g332809
1. Park the machine on a level surface. Stop the engine, wait for all moving
parts to stop and remove the key.
Do not flip the snowthrower on the auger housing. Damage to the
hydrostat may occur.
2. Using a overhead lifting device, raise the unit off the floor.
Figure 10
Figure 11
CAUTION
Page 5–6
POWER TRX™ HD Service Manual
3440-740 Rev A