QuadTech Guardian 2500 Series Instruction Manual page 27

Ac/dc/ir hipot tester
Table of Contents

Advertisement

Condensed Operating Instructions (continued)
4. Test Results Summary Display with Sequence Test Selected (S1 – S9)
Sequence 1 (S1) shown in example below.
S1: Pass 1 2 3
Fail
None
PASS
If limits are not exceeded
PASS Light ON
To view test results, press
arrow to review test 1 – 3
of the sequence.
Unit is ready for another test
to be initiated
If "Continue Voltage On Fail" is enabled a "Fail" on the summary display (as shown
for Test 1 above) can be a conditional Pass. A conditional pass occurs if, during one of
the tests within the sequence, the device failed at some point but was passing at the end
When reviewing individual test results with up/down arrow as described above an
asterisk following the Pass would indicate the conditional Pass. This would only be seen
with "Continue Voltage On Fail" enabled. Refer to Continue Voltage On Fail,
S1: Pass 2 3
Fail
If limits are exceeded
FAIL Light On
To view test results, press STOP
button, then
1 – 3 tests of the sequence.
Press STOP button second time to
reset before another test can be initiated.
NOTE
of the test.
paragraph 2.4.9, step 3.
1
0.325KV
AC Tot * 0.005mA
1
FAIL
arrow to review
Pass*
0.0s
Page 27 of 27