List Of The Private Parameters For Konfort 780R Bigas; Public Parameters" Function On Konfort 700R Units - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual

4.6.6 List of the private parameters for Konfort 780R BiGas

MAX ABSOLUTE WEIGHT MAIN TANK
MAX ABSOLUTE WEIGHT SECOND TANK
OTHER OILS
CLEANING TIME
FIRST RECOVERY TIME
USED OIL PHASE
RECOVERY CLEANING TIME
HOSES CLEANING TIME
VACUUM TIME FOR FLUXING
MINIMUM WEIGHT FOR FLUXING
AUTOCALIBRATION THRESHOLD (10 pt.)
ON TIME LP PRESSURE CHARGING PHASE (0.1 sec.)
RECOVERY PHASE WAITING TIME
RECOVERY PHASE FINAL TIME
CHECK WAITING TIME
IO/UV DELAY TIME (0.01 sec.)
REFR. IDENTIFIER CALIBRATION THRESHOLD T(h)
MAX FAILED DRAIN RETRIES
LEAK TIME FOR FLUXING
FORCE DISCHARGE BEFORE RECOVERY
ANALYZE GAS
PRE VACUUM TIME
Table 4.6 – List of the private parameters for Konfort 780R BiGas
4.7

"PUBLIC PARAMETERS" function on Konfort 700R units

The Public parameters function, available from the Service menu,
allows user to check the value of some standard functional parameters of
the equipment.
The following subparagraphs will report the default values for the public
parameters of each model of Konfort 700R units. The changing of each
parameter will be possible by simply editing the new value and by
confirming with the ENTER button.
WARNING! The public parameters change implies a modification of
the behavior of the unit. Please, contact TEXA Technical Assistance
for being instructed in any parameter change.
Copyright © 2014 – TEXA S.p.A.
PARAMETER
89
TEXA Technical Assistance
DEFAULT
VALUE
gr. 25000
gr. 25000
sec. 10
sec. 30
sec. 40
sec. 90
sec. 75
min. 5
Kg. 5
sec. 20
sec. 20
sec. 2
min. 3
min. 15
3
15
5
30
0
4
0
1

Advertisement

Table of Contents
loading

Table of Contents