Leak Test; Oil Injection - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual

2.2.4 Leak Test

During this phase, the equipment activates only the pressure sensor (1).
Spent the amount of time set for the vacuum phase, the vacuum pump
turns off and the two electro-valves EVP01 and EVP02 close. At this
point, the pressure sensor performs a further control of pressure inside
the A/C system (for an amount of time preventively selected from the
initial menu of the equipment).
If, within this laps of time, the pressure rises above the limit value of
120mBars absolute, the unit will automatically stop the cycle, by putting
itself into a stand-by state and by alerting the operator (by means of a
beep and of a special message on the display) about
(indicative, in this case, of a possible leak on the A/C system of the
vehicle). If, on the other hand, the remaining pressure is below this
threshold, the operative cycle of the Konfort unit automatically switches
to the next step.
Image 2.5 – Part of the hydraulic circuit involved into the leak test

2.2.5 Oil Injection

During this phase, the equipment activates the following electrical
components:
Pressure sensor (1);
LP electro-valves (only for 760R, 760R Bus and 780R BiGas);
HP electro-valves (only for 760R, 760R Bus and 780R BiGas);
EVIO electro-valve;
Copyright © 2014 – TEXA S.p.A.
TEXA Technical Assistance
15
the anomaly

Advertisement

Table of Contents