Uv Additive" Calibration On K710R And K720R; New Oil" Calibration On K705R, K710R And K720R; Main Sensor" Calibration On K705R, K710R And K720R - TEXA Konfort 700R Series Manual

Hide thumbs Also See for Konfort 700R Series:
Table of Contents

Advertisement

Konfort Series 700R Service Manual
TEXA Technical Assistance
The unit will show the following screenshot:
P l e a s e
w a i t !
Image 4.32 – Waiting message during calibration of the refrigerant load cell
in a Konfort 705R, 710R or 720R
followed by the message here below:
C a l i b r a t i o n
O K !
Image 4.33 – Confirmation message of the correctness of the calibration
thus confirming the correctness of the procedure.

4.4.2 "UV ADDITIVE" calibration on K710R and K720R

Although not equipped with a scale for the management of the amount of
UV additive that is injected during a service on the A/C system of a
vehicle, Konfort 710R and 720R units allow in any case the calibration of
the time constant which controls the opening of the EVUV electro-valve.

4.4.3 "NEW OIL" calibration on K705R, K710R and K720R

Although not equipped with a scale for the management of the amount of
oil that is injected during a service on the A/C system of a vehicle,
Konfort 705R, 710R and 720R units allow in any case the calibration of
the time constant which controls the opening of the EVIO electro-valve.

4.4.4 "MAIN SENSOR" calibration on K705R, K710R and K720R

The Main Sensor function available in the Sensor calibration menu
allows user to calibrate the main pressure sensor of equipment.
58
Copyright © 2014 – TEXA S.p.A.

Advertisement

Table of Contents
loading

Table of Contents