For each sensor, on the line just below, the unit reports the status of the
corresponding calibration:
1 = the sensor is correctly calibrated;
0 = the sensor is not calibrated, it is necessary to check its proper
functioning.
4.9

"SELECT REFRIGERANT" function on Konfort 700R units

The Select Refrigerant function, available from the Service menu with
the dealer password, allows to select the type of refrigerant with which
the user would like to make the unit to operate. The options available
are:
R134a : by choosing this option, the GAS light on the top panel of
the unit will be colored in ORANGE;
R1234yf : by choosing this option, the GAS light on the top panel of
the unit will be colored in GREEN.
This function has to be used on Konfort 720R, 760R and 760R Bus units
for changing the type of refrigerant to be employed by the unit, for
example after the retrofit operation from R134a to R1234yf.

4.10 "STORED ERRORS" function on Konfort 700R units

The Stored errors function, available from the Service menu both with
the user password 1236 and with the dealer one (provided every year by
TEXA S.p.A), allows to display the history of the functioning faults of the
unit:
Image 4.89 – Example of the Stored errors function
Copyright © 2014 – TEXA S.p.A.
on Konfort 700R units
97